The Metravi 1813 ELCB RCD Tester has the main function of testing and measuring the trip values of ELCB/RCCB in trip time (expressed in ms) or -in trip current value (expressed in mA).
This enables 10mA / 30mA / 100mA / 300mA / 500mA and 1000mA differential circuit breakers to be tested irrespective of their type (normal or delayed). This comprehensive appliance can also be used to test the conformity of the network and the connection of the earthing conductor.
Additional information
Model
1813
Brand
Metravi
Colour
Blue-Black
Display
3-digit measurement display
Wiring Check
Locking and Warning Signals
Operating Voltage
230V (Ph/N) –10/+6%, 50/60 Hz
Trip Current Setting
10/30/100/300/500mA, 1A
Trip Time Range
10–2000ms (0.5x), 10–500ms (1x)
Ramp Test Mode
0.4x–1.4x Nominal rated Current
Accuracy
(–2% +10% rdg) + 6 Digits
Safety Certifications
CAT III 600V, IEC 61010-1, IEC 61557-6
Phase Angle
0° and 180°
Power Supply
6 x 1.5V ‘AA’ batteries
Data Hold
Automatic Data Hold Function
Features Present
Double insulation, locking signals, 400V warning
Test Types
N or S type RDD test, AC or A detection
Specifications
Display: 3 digits Backlit LCD
N or S (delayed) type RDD test, – AC or A (continuous component detection).
Operates on TT neutral and TN system.
Operating Voltage: 230V (Ph/N) – 10/+6% 50/60 Hz.
Nominal Test Current: 10mA/30mA/100mA/300mA/500mA/1A
Accuracy: (-2%+10%) + 6Digits
Trip Time:
10-2000 ms at 0.5x
10-500 ms at 1x
10-150 ms at 2x
10-40 ms at 5x
Ramp Test: 0.4x to 1.4 times nominal rated current
Protection: Double insulation, IP40
Certifications: CAT III 600V, IEC 61010-1. IEC 61557-6 NF. EN 61557-6. IEC 61236 (EMC).
Locking and warning signals for 400V network voltage and contact potential >50V.
Test and measure the trip values of RDDS (Residual Differential Devices): -in trip time (expressed in ms ) or -in trip current value (expressed in mA).
The Metravi 1813 ELCB RCD Tester has the main function of testing and measuring the trip values of ELCB/RCCB in trip time (expressed in ms) or -in trip current value (expressed in mA).
This enables 10mA / 30mA / 100mA / 300mA / 500mA and 1000mA differential circuit breakers to be tested irrespective of their type (normal or delayed). This comprehensive appliance can also be used to test the conformity of the network and the connection of the earthing conductor.
Additional information
Model
1813
Brand
Metravi
Colour
Blue-Black
Display
3-digit measurement display
Wiring Check
Locking and Warning Signals
Operating Voltage
230V (Ph/N) –10/+6%, 50/60 Hz
Trip Current Setting
10/30/100/300/500mA, 1A
Trip Time Range
10–2000ms (0.5x), 10–500ms (1x)
Ramp Test Mode
0.4x–1.4x Nominal rated Current
Accuracy
(–2% +10% rdg) + 6 Digits
Safety Certifications
CAT III 600V, IEC 61010-1, IEC 61557-6
Phase Angle
0° and 180°
Power Supply
6 x 1.5V ‘AA’ batteries
Data Hold
Automatic Data Hold Function
Features Present
Double insulation, locking signals, 400V warning
Test Types
N or S type RDD test, AC or A detection
Specifications
Display: 3 digits Backlit LCD
N or S (delayed) type RDD test, – AC or A (continuous component detection).
Operates on TT neutral and TN system.
Operating Voltage: 230V (Ph/N) – 10/+6% 50/60 Hz.
Nominal Test Current: 10mA/30mA/100mA/300mA/500mA/1A
Accuracy: (-2%+10%) + 6Digits
Trip Time:
10-2000 ms at 0.5x
10-500 ms at 1x
10-150 ms at 2x
10-40 ms at 5x
Ramp Test: 0.4x to 1.4 times nominal rated current
Protection: Double insulation, IP40
Certifications: CAT III 600V, IEC 61010-1. IEC 61557-6 NF. EN 61557-6. IEC 61236 (EMC).
Locking and warning signals for 400V network voltage and contact potential >50V.
Test and measure the trip values of RDDS (Residual Differential Devices): -in trip time (expressed in ms ) or -in trip current value (expressed in mA).