Fluke 17B MAX Inherits and continues the classic design of 17B+, with further improved functions: Input Alert Alarm, Simple interface to wake meter from sleep mode by activating any buttons, test leads with fine probes to help electricians and electronic R&D personnel make accurate measurements.
Key features
Audible and visual alarm for incorrect connections
Test leads with fines tips for circuit board testing
Simple interface to wake meter from sleep mode by activating any buttons
Fluke 17B MAX Inherits and continues the classic design of 17B+, with further improved functions: Input Alert Alarm, Simple interface to wake meter from sleep mode by activating any buttons, test leads with fine probes to help electricians and electronic R&D personnel make accurate measurements.
Key features
Audible and visual alarm for incorrect connections
Test leads with fines tips for circuit board testing
Simple interface to wake meter from sleep mode by activating any buttons
Voltage: 6000-count reading
Capacitance range: 2000uF
Safety rating: CATIII 600V
Frequency and temperature measurement
Specifications
Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, relative humidity at 0 % to 75 % Accuracy specifications take the form of: ± ([% of Reading] + [Number of Least Significant Digits]).
Function
Range
Resolution
Accuracy
15B MAX
17B MAX
AC Volts (40 Hz to 500 Hz)1
6.000 V
0.001 V
1.0 % + 3
1.0 % + 3
60.00 V
0.01 V
600.0 V
0.1 V
1000 V
1 V
AC Millivolts
600.0 mV
0.1 mV
3.0 % + 3
3.0 % + 3
DC Volts
6.000 V
0.001 V
0.5 % + 3
0.5 % + 3
60.00 V
0.01 V
600.0 V
0.1 V
1000 V
1 V
DC Millivolts
600.0 mV
0.1 mV
1.0 % + 10
1.0 % + 10
AC Current μA (40 Hz to 400 Hz)2
400.0 μA
0.1 μA
1.5 % + 3
1.5 % + 3
4000 μA
1 μA
AC Current mA (40 Hz to 400 Hz)2
40.00 mA
0.01 mA
1.5 % + 3
1.5 % + 3
400.0 mA
0.1 mA
AC Current A (40 Hz to 400 Hz)2
4.000 A
0.001 A
1.5 % + 3
1.5 % + 3
10.00 A
0.01 A
DC Current μA2
400.0 μA
0.1 μA
1.5 % + 3
1.5 % + 3
4000 μA
1 μA
DC Current mA2
40.00 mA
0.01 mA
1.5 % + 3
1.5 % + 3
400.0 mA
0.1 mA
DC Current A2
4.000 A
0.001 A
1.5 % + 3
1.5 % + 3
10.00 A
0.01 A
Diode Test3
2.000 V
0.001 V
10%
10%
Temperature 4
50.0 °C to 400.0 °C 0 °C to 50.0 °C -55.0 °C to 0 °C
0.1 °C
NA
2 %+1 °C 2 °C 9 %+2 °C
Resistance (Ohms)5
400.0 Ω
0.1 Ω
0.5 % + 3
0.5 % + 3
4.000 kΩ
0.001 kΩ
0.5 % + 2
0.5 % + 2
40.00 kΩ
0.01 kΩ
0.5 % + 2
0.5 % + 2
400.0 kΩ
0.1 kΩ
0.5 % + 2
0.5 % + 2
4.000 MΩ
0.001 MΩ
0.5 % + 2
0.5 % + 2
40.00 MΩ
0.01 MΩ
1.5 % + 3
1.5 % + 3
Capacitance6
40.00 nF
0.01 nF
2 % + 5
2 % + 5
400.0 nF
0.1 nF
2 % + 5
2 % + 5
4.000 μF
0.001 μF
5 % + 5
5 % + 5
40.00 μF
0.01 μF
5 % + 5
5 % + 5
400.0 μF
0.1 μF
5 % + 5
5 % + 5
2000 μF
1 μF
5 % + 5
5 % + 5
Frequency1 (10 Hz to 100 kHz)
50.00 Hz
0.01 Hz
NA
0.1 % + 3
500.0 Hz
0.1 Hz
5.000 kHz
0.001 kHz
50.00 kHz
0.01 kHz
100.0 kHz
0.1 kHz
Duty Cycle1
1% to 99%
0.10%
NA
1 % typical7
Continuity Threshold
—
—
70Ω
70Ω
Backlight
—
—
Yes
Yes
All ac, Hz, and duty cycle are specified from 1 % to 100 % of range. Inputs below 1 % of range are not specified.
Typical burden voltage: DC/AC Current µA: 100 µV / µA; DC/AC Current mA: 2 mV/mA; DC/AC Current A: 0.03 V/A
Typically, open circuit test voltage is 2.0 V and short circuit current is <0.6 mA
Use Type K thermocouple
Typical open circuit test voltage is 0.54 V, maximum short circuit current is 1.8 mA
Specifications do not include errors due to test lead capacitance and capacitance floor (may be up to 1.5 nF in the 40 nF range).
Typical means when the frequency is at 50 Hz or 60 Hz and the duty cycle is between 10 % and 90 %.
Input Characteristics
Function
Overload Protection
Input Impedance (Nominal)
Common Mode Rejection Ratio
Normal Mode Rejection Ratio
AC Volts
1000 V 1
>10 MΩ, <100 pF
>60 dB at 50 Hz or 60 Hz
-
AC Millivolts
1000 V 1
>1 MΩ, <100 pF
>80 dB at 50 Hz or 60 Hz
—
DC Volts
1000 V 1
>10 MΩ, <100 pF
>100 dB at 50 Hz or 60 Hz
>60 dB at 50 Hz or 60 Hz
DC Millivolts
1000 V 1
>1 MΩ, <100 pF
>80 dB at 50 Hz or 60 Hz
—
General Specifications
Maximum voltage between any Terminal and Earth Ground
600 V
Maximum differential voltage between V and COM terminals
1000V
Display (LCD)
6000 counts, updates 3/sec
Battery Type
2 AA, IEC LR6
Battery life
500 hours minimum
Temperature
Operating 0 °C to 40 °C;
Storage -30 °C to 60 °C
Relative Humidity
Operating Humidity Non-condensing
(<10 °C); ≤90 % RH at 10 °C to 30 °C; ≤75 % RH at 30 °C to 40 °C
Operating Humidity, 40 MΩ range
≤80 % RH at 10 °C to 30 °C; ≤70 % RH at 30 °C to 40 °C
Altitude
Operating 2000 m; Storage 12000 m
Temperature Coefficient
0.1 X (specified accuracy) /°C (<18 °C or >28 °C)
Fuse protection for current inputs
440 mA, 1000 V, fast-blow, use only Fluke specified parts. 11 A, 1000 V, fast-blow, use only Fluke specified parts
Size (HxWxL)
183 mm x 91 mm x 49.5 mm
Weight
455 g
Ingress Protection
IP40
Safety
IEC 61010-1, IEC61010-2-030: CAT III 600 V, Pollution Degree 2