• -0%

Fluke -15B+ Digital Multimeter

SKU
15B+
In stock
₹ 11,300.00 (Inc. GST)
Overview

Descriptions

Fluke quality is always within your reach

Unlock professional-grade precision, durability, and safety with the Fluke 15B+ Digital Multimeter. The Fluke 15B+ packs all the core functionality you need in a digital multimeter into a portable, rugged form tool that’s easy-to-use with one hand, even with gloves on. From AC/DC voltage and current measurements up to 1000V and 10A, to comprehensive capabilities including resistance, capacitance, and frequency checks, the 15B+ is your go-to for troubleshooting a wide array of electrical issues.

The CAT III 600V safety rating provides peace of mind for everything from routine checks on electrical equipment and appliances, to checking voltage levels at power outlets or switches, to diagnosing issues with circuits. Ideal for both DIY enthusiasts and early career electricians looking to streamline their toolkit, the Fluke 15B+ is a reliable and versatile addition to your toolkit.

 

 

Key features

  • 600 V Cat III safety rating

  • AC/DC voltage measurement up to 1000V

  • AC/DC current measurement up to 10A

  • Measures voltage, resistance, continuity, capacitance

  • Diode test, data hold

  • Large easy-to-read display with bright white backlight

 

 

Specifications

Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, relative humidity at 0% to 75%. Accuracy specifications take the form of: ±(% of Reading + Number of Least Significant Digits).

Function

Range

Resolution

Accuracy

AC volts
(40 Hz to 500Hz)1
4.000 V 0.001 V 1.0% + 3
40.00 V 0.01 V
400.0 V 0.1 V
1000 V 1 V
DC volts 4.000 V 0.001 V 0.5% + 3
40.00 V 0.01 V
400.0 V 0.1 V
1000 V 1 V
AC millivolts 400.0 mV 0.1 mV 3.0% + 3
DC millivolts 400.0 mV 0.1 mV 1.0% + 10
Diode test2 2.000 V 0.001 V 10%
Resistance
(Ohms)
400.0 Ω 0.1 Ω 0.5% + 3
4.000 kΩ 0.001 kΩ 0.5% + 2
40.00 kΩ 0.01 kΩ 0.5% + 2
400.0 kΩ 0.1 kΩ 0.5% + 2
4.000 MΩ 0.001 MΩ 0.5% + 2
40.00 MΩ 0.01 MΩ 1.5% + 3
Capacitance3 40.00 nF 0.01 nF 2% + 5
400.0 nF 0.1 nF 2% + 5
4.000 μF 0.001 μF 5% + 5
40.00 μF 0.01 μF 5% + 5
400.0 μF 0.1 μF 5% + 5
1000 μF 1 μF 5% + 5
AC current μA
(40 Hz to 400 Hz)
400.0 μA 0.1 μA 1.5% + 3
4000 μA 1 μA
AC current mA
(40 Hz to 400 Hz)
40.00 mA 0.01 mA 1.5% + 3
400.0 mA 0.1 mA
AC current A
(40 Hz to 400 Hz)
4.000 A 0.001 A 1.5% + 3
400.0 mA 0.1 mA
AC current A
(40 Hz to 400 Hz)
4.000 A 0.001 A 1.5% + 3
10.00 A 0.01 A
DC current μA 400.0 μA 0.1 μA 1.5% + 3
4000 μA 1 μA
DC current mA 40.00 mA 0.01 mA 1.5% + 3
400.0 mA 0.1 mA
DC current A 4.000 A 0.001 A 1.5% + 3
10.00 A 0.01 A
Backlight Yes

 

  1. AC volts are specified from 1% to 100% of range. Inputs below 1% of range are not specified.

  2. Typically, open circuit test voltage is 2.0 V and short circuit current is <0.6 mA.

  3. Specifications do not include errors due to test lead capacitance and capacitance floor (may be up to 1.5 nF in the 40 nF range).

 

Function

Overload protection

Input impedance (Nominal)

Common mode rejection ratio

Normal mode rejection ratio

AC volts 1000 V 1 >10 MΩ <100 pF >60 dB at dc,
50 Hz or 60 Hz
-
AC millivolts 400 mV >1MΩ, <100 pF >80 dB at 50 Hz or 60 Hz -
DC volts 1000 V 1 >10 MΩ <100 pF >100 dB at dc,
50 Hz or 60 Hz
>60 dB at 50 Hz or 60 Hz
DC millivolts 400 mV >1MΩ, <100 pF >80 dB at 50 Hz or 60 Hz -

 

  1. 106 V Hz Max

 

General specifications

Maximum voltage between any terminal and earth ground 1000 V
Display (LCD) 4000 counts, updates 3/sec
Battery type 2 AA, NEDA 15A, IEC LR6
Battery life 500 hours minimum
Temperature
Operating 0 °C to 40 °C
Storage -30 °C to 60 °C

Relative humidity

Operating humidity Non-condensing (<10°C)
≤90% RH at 10 °C to 30 °C;
≤75% RH at 30 °C to 40 °C
40 MΩ range
≤80% RH at 10 °C to 30 °C;
≤70% RH at 30 °C to 40 °C

Altitude

Operating 2000 m
Storage 12,000 m
Temperature coefficient 0.1 X (specified accuracy) /°C (<18 °C or >28 °C)
Fuse protection for current inputs 440 mA, 1000 V Fast Fuse, Fluke specified part only.
11A, 1000V Fast Fuse, Fluke specified part only.
Size (H x W x L) 183 x 91 x 49.5 mm
Weight 455 g
IP rating IP 40
Safety IEC 61010-1, IEC61010-2-030 CAT III 600 V, Pollution Degree 2
Electromagnetic Compatibility IEC 61326-1: Portable EMC Environment

 

 

 

 

 

 

Descriptions

Fluke quality is always within your reach

Unlock professional-grade precision, durability, and safety with the Fluke 15B+ Digital Multimeter. The Fluke 15B+ packs all the core functionality you need in a digital multimeter into a portable, rugged form tool that’s easy-to-use with one hand, even with gloves on. From AC/DC voltage and current measurements up to 1000V and 10A, to comprehensive capabilities including resistance, capacitance, and frequency checks, the 15B+ is your go-to for troubleshooting a wide array of electrical issues.

The CAT III 600V safety rating provides peace of mind for everything from routine checks on electrical equipment and appliances, to checking voltage levels at power outlets or switches, to diagnosing issues with circuits. Ideal for both DIY enthusiasts and early career electricians looking to streamline their toolkit, the Fluke 15B+ is a reliable and versatile addition to your toolkit.

 

 

Key features

  • 600 V Cat III safety rating

  • AC/DC voltage measurement up to 1000V

  • AC/DC current measurement up to 10A

  • Measures voltage, resistance, continuity, capacitance

  • Diode test, data hold

  • Large easy-to-read display with bright white backlight

 

 

Specifications

Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, relative humidity at 0% to 75%. Accuracy specifications take the form of: ±(% of Reading + Number of Least Significant Digits).

Function

Range

Resolution

Accuracy

AC volts
(40 Hz to 500Hz)1
4.000 V 0.001 V 1.0% + 3
40.00 V 0.01 V
400.0 V 0.1 V
1000 V 1 V
DC volts 4.000 V 0.001 V 0.5% + 3
40.00 V 0.01 V
400.0 V 0.1 V
1000 V 1 V
AC millivolts 400.0 mV 0.1 mV 3.0% + 3
DC millivolts 400.0 mV 0.1 mV 1.0% + 10
Diode test2 2.000 V 0.001 V 10%
Resistance
(Ohms)
400.0 Ω 0.1 Ω 0.5% + 3
4.000 kΩ 0.001 kΩ 0.5% + 2
40.00 kΩ 0.01 kΩ 0.5% + 2
400.0 kΩ 0.1 kΩ 0.5% + 2
4.000 MΩ 0.001 MΩ 0.5% + 2
40.00 MΩ 0.01 MΩ 1.5% + 3
Capacitance3 40.00 nF 0.01 nF 2% + 5
400.0 nF 0.1 nF 2% + 5
4.000 μF 0.001 μF 5% + 5
40.00 μF 0.01 μF 5% + 5
400.0 μF 0.1 μF 5% + 5
1000 μF 1 μF 5% + 5
AC current μA
(40 Hz to 400 Hz)
400.0 μA 0.1 μA 1.5% + 3
4000 μA 1 μA
AC current mA
(40 Hz to 400 Hz)
40.00 mA 0.01 mA 1.5% + 3
400.0 mA 0.1 mA
AC current A
(40 Hz to 400 Hz)
4.000 A 0.001 A 1.5% + 3
400.0 mA 0.1 mA
AC current A
(40 Hz to 400 Hz)
4.000 A 0.001 A 1.5% + 3
10.00 A 0.01 A
DC current μA 400.0 μA 0.1 μA 1.5% + 3
4000 μA 1 μA
DC current mA 40.00 mA 0.01 mA 1.5% + 3
400.0 mA 0.1 mA
DC current A 4.000 A 0.001 A 1.5% + 3
10.00 A 0.01 A
Backlight Yes

 

  1. AC volts are specified from 1% to 100% of range. Inputs below 1% of range are not specified.

  2. Typically, open circuit test voltage is 2.0 V and short circuit current is <0.6 mA.

  3. Specifications do not include errors due to test lead capacitance and capacitance floor (may be up to 1.5 nF in the 40 nF range).

 

Function

Overload protection

Input impedance (Nominal)

Common mode rejection ratio

Normal mode rejection ratio

AC volts 1000 V 1 >10 MΩ <100 pF >60 dB at dc,
50 Hz or 60 Hz
-
AC millivolts 400 mV >1MΩ, <100 pF >80 dB at 50 Hz or 60 Hz -
DC volts 1000 V 1 >10 MΩ <100 pF >100 dB at dc,
50 Hz or 60 Hz
>60 dB at 50 Hz or 60 Hz
DC millivolts 400 mV >1MΩ, <100 pF >80 dB at 50 Hz or 60 Hz -

 

  1. 106 V Hz Max

 

General specifications

Maximum voltage between any terminal and earth ground 1000 V
Display (LCD) 4000 counts, updates 3/sec
Battery type 2 AA, NEDA 15A, IEC LR6
Battery life 500 hours minimum
Temperature
Operating 0 °C to 40 °C
Storage -30 °C to 60 °C

Relative humidity

Operating humidity Non-condensing (<10°C)
≤90% RH at 10 °C to 30 °C;
≤75% RH at 30 °C to 40 °C
40 MΩ range
≤80% RH at 10 °C to 30 °C;
≤70% RH at 30 °C to 40 °C

Altitude

Operating 2000 m
Storage 12,000 m
Temperature coefficient 0.1 X (specified accuracy) /°C (<18 °C or >28 °C)
Fuse protection for current inputs 440 mA, 1000 V Fast Fuse, Fluke specified part only.
11A, 1000V Fast Fuse, Fluke specified part only.
Size (H x W x L) 183 x 91 x 49.5 mm
Weight 455 g
IP rating IP 40
Safety IEC 61010-1, IEC61010-2-030 CAT III 600 V, Pollution Degree 2
Electromagnetic Compatibility IEC 61326-1: Portable EMC Environment

 

 

 

 

 

 

More Information
SKU 15B+
SIZE 4-50mm
Product Model No 15B+
brand Fluke
Write Your Own Review