A compact trms digital multimeter for field service technicians
The Fluke 115 technicians digital multimeter is the compact, general purpose troubleshooting tool for field service technicians. Its simple, one-handed operation and compact design meets the needs of a wide variety of field service technicians. It measures True RMS voltage and current with 6000 count resolution as well as resistance, continuity, frequency and capacitance for quick verifications.
The Fluke 110 Series has five true-rms digital multimeters, each for specific users. The compact instruments offer convenient one-handed operation and a backlit display with large, easy-to-read digits.
Key Features
The 115 digital multimeter is for electrical and electronic testing in field service, industrial and applications where more than the basic functions are needed.
Ideal for quick verifications and field service
Min/Max/Average to record signal fluctuations
CAT III 600V
General purpose digital multimeter for electrical and electronic testing
Ideal for quick verifications and field service
Presents a large white LED backlight for working in poorly lit areas
Measures AC and DC voltage to 600V
Measures AC and DC current to 10A (20 A overload for 30-seconds max)
Measures resistance, continuity, frequency, and capacitance
Provides Min/Max/Average with elapsed time to record signal fluctuations
Comes with a holster with probe holders for easy storage
Features a compact ergonomic design for one-handed operation
Fits into optional ToolPak™ magnetic hanger for hands-free operation
CAT III 600 V safety rated
For field service technicians, basic electronic repair.
A compact trms digital multimeter for field service technicians
The Fluke 115 technicians digital multimeter is the compact, general purpose troubleshooting tool for field service technicians. Its simple, one-handed operation and compact design meets the needs of a wide variety of field service technicians. It measures True RMS voltage and current with 6000 count resolution as well as resistance, continuity, frequency and capacitance for quick verifications.
The Fluke 110 Series has five true-rms digital multimeters, each for specific users. The compact instruments offer convenient one-handed operation and a backlit display with large, easy-to-read digits.
Key Features
The 115 digital multimeter is for electrical and electronic testing in field service, industrial and applications where more than the basic functions are needed.
Ideal for quick verifications and field service
Min/Max/Average to record signal fluctuations
CAT III 600V
General purpose digital multimeter for electrical and electronic testing
Ideal for quick verifications and field service
Presents a large white LED backlight for working in poorly lit areas
Measures AC and DC voltage to 600V
Measures AC and DC current to 10A (20 A overload for 30-seconds max)
Measures resistance, continuity, frequency, and capacitance
Provides Min/Max/Average with elapsed time to record signal fluctuations
Comes with a holster with probe holders for easy storage
Features a compact ergonomic design for one-handed operation
Fits into optional ToolPak™ magnetic hanger for hands-free operation
CAT III 600 V safety rated
For field service technicians, basic electronic repair.
Specifications
Accuracy Specifications
DC millivolts
Range/resolution
600.0 mV / 0.1 mV
Accuracy
± ([% of reading] + [counts]): 0.5% + 2
DC volts
Range/resolution
6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 V
Accuracy
± ([% of reading] + [counts]): 0.5% + 2
AC millivolts1 True RMS
Range/resolution
600.0 mV / 0.1 mV
Accuracy
1.0% + 3 (DC, 45 Hz to 500 Hz)
2.0% + 3 (500 Hz to 1 kHz)
AC volts1 True RMS
Range/resolution
6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 V
Accuracy
1.0% + 3 (DC, 45 Hz to 500 Hz)
2.0% + 3 (500 Hz to 1 kHz)
Continuity
Range/resolution
600 Ω / 1 Ω
Accuracy
Beeper on < 20 Ω, off > 250 Ω detects opens or shorts of 500 μs or longer.
Ohms
Range/resolution
600.0 Ω / 0.1 Ω
6.000 kΩ / 0.001 kΩ
60.00 kΩ / 0.01 kΩ
600.0 kΩ / 0.1 kΩ
6.000 MΩ / 0.001 MΩ
Accuracy
0.9% + 1
Range/resolution
40.00 MΩ / 0.01 MΩ
Accuracy
5% + 2
Diode test
Range/resolution
2.00 V / 0.001 V
Accuracy
0.9% + 2
Capacitance
Range/resolution
1000 nF / 1 nF
10.00 μF / 0.01 μF
100.0 μF / 0.1 μF
9999 μF / 1 μF
100 μF to 1000 μF
Accuracy
1.9% + 2
Range/resolution
> 1000 μF
Accuracy
5% + 20%
Lo-Z capacitance
Range
1 nF to 500 μF
Accuracy
10% + 2 typical
AC amps True RMS (45 Hz to 500Hz)
Range/resolution
6.000 A / 0.001 A
10.00 A / 0.01 A
Accuracy
1.5% + 3
20 A overload for 30-seconds max
DC amps
Range/resolution
6.000 A / 0.001 A
10.00 A / 0.01 A
Accuracy
1.0% + 3
20 A overload for 30-seconds max
Hz (V or A input)2
Range/resolution
99.99 Hz / 0.01 Hz
999.9 Hz / 0.01 Hz
9.999 kHz / 0.001 kHz
50.00 kHz / 0.01 kHz
Accuracy
0.1% + 2
All AC voltage ranges except Auto-V/LoZ are specified from 1% to 100% of range. Auto-V/LoZ is specified from 0.0 V.
Frequency is AC coupled, 5Hz to 30 kHz for AC voltage.
Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.
Frequency is AC coupled, 5 Hz to 50 kHz for AC voltage. Frequency is DC coupled, 45 Hz to 5 kHz for AC current.
Temperature Range/Resolution: -40℉ to 752℉ / 0.2℉.
General Specifications