The Fluke 107 is a compact, palm size easy-to-use digital multimeter made to fit the way you work. It is the perfect first-pass troubleshooting tool; small enough to fit in a shirt pocket yet tough enough to withstand daily use, including a 1-meter drop test. For everyday applications where true-rms accuracy isn’t needed, the Fluke 107 delivers reliable measurements time after time. With a CAT III 600 V safety rating, you don’t need to compromise safety. The Fluke 107 offers a comfortable grip, weight only 200 g, and is easy to carry.
Key features
CAT III 600 V safety rating
Current and voltage measurements
Measures resistance and continuity to check for broken wires
Data hold and backlit display to keep you working safe and fast
AC and DC voltage
AC and DC current
Resistance
Capacitance
Diode
Frequency and duty-cycle
Fluke 107 comes ready to work
The Fluke 107 comes with a TL75 Hard Point™ Test Lead Set. It’s one pair (red, black) of 48 inch (1.22 meter) test leads with right-angle, shrouded banana plugs. The meter also includes a SmartStrap™ intelligent magnetic multi-purpose lanyard that lets you hang the Fluke 107 from any ferrous surface or support the meter at an angle for easy viewing.
Specifications
Precision specifications
AC voltage(40 Hz to 500 Hz)1
Range
Resolution
Accuracy
6.000 V
0.001 V
1.0 % + 3
60.00 V
0.01 V
600.0 V
0.1 V
DC voltage
6.000 V
0.001 V
0.5 % + 3
60.00 V
0.01 V
600.0 V
0.1 V
Exchange millivolts
600.0 mV
0.1 mV
3.0 % + 3
Diode test2
2.000 V
0.001 V
10 %
Resistance (ohm)
400.0 Ω
0.1 Ω
0.5 % + 3
4.000 kΩ
0.001 kΩ
0.5 % + 2
40.00 kΩ
0.01 kΩ
0.5 % + 2
400.0 kΩ
0.1 kΩ
0.5 % + 2
4.000 MΩ
0.01 MΩ
1.5% + 3
Capacitor3
50.00 nF
0.01 nF
2 % + 5
500.0 nF
0.1 nF
2 % + 5
5.000 μF
0.001 μF
5 % + 5
50.00 μF
0.01 μF
5 % + 5
500.0 μF
0.1 μF
5 % + 5
1000 μF
1 μF
5 % + 5
Frequency4 Hz (10 Hz – 100 kHz)
50.00 Hz
0.01 Hz
0.1 % + 3
500.0 Hz
0.1 Hz
5.000 kHz
0.001 kHz
50.00 kHz
0.01 kHz
100.0 kHz
0.1 kHz
Duty cycle4
1 % to 99 %
0.10 %
1 % typical case5
AC current (40 Hz - 200 Hz)
4.000 A
0.001 A
1.5 % + 3
10.00 A
0.01 A
DC
4.000 A
0.001 A
1.5 % + 3
10.00 A
0.01 A
All AC current, frequency, and duty cycle are specified from 1% to 100% of the range. Input values below 1% of range are not specified.
Typically, the open circuit test voltage is 2.0 V and the short circuit current is < 0.6 mA.
The parameters do not include errors due to test lead capacitance and capacitor substrate (up to 1.5 nF in the 50 nF range).
All AC current, frequency, and duty cycle are specified from 1% to 100% of the range. Input values below 1% of range are not specified.
Typically, the frequency is 50 Hz or 60 Hz and the duty cycle is 10% to 90%.
Features
Overload protection
Input impedance (nominal value)
Common mode rejection ratio
Normal mode rejection ratio
AC voltage
600 V 1
>10 MΩ <100 pF 2
>60 dB at 50 Hz or 60 Hz at DC current
-
Exchange millivolts
600 mV
>1M, <100 pF
>80 dB at 50 Hz or 60 Hz
-
DC voltage
600 V 1
>10 MΩ <100 pF
>100 dB at 50 Hz or 60 Hz at DC current
>60 dB at 50 Hz or 60 Hz
Up to 6 x 105 V Hz
For medium voltage (alternating current), the input impedance is approximately 1 MΩ.
General technical indicators
The highest voltage applied to any terminal and ground
600 V
Display (LCD)
6000 counts, updated three times per second
Type of battery
Two AAA batteries (NEDA 24A, IEC LR03)
Battery life
200 hours
Temperature
Operating temperature
0 °C to 40 °C
Storage temperature
-30 °C to 60 °C
Relative humidity
Working humidity
No condensation below 10 °C ≤ 90 % at 10 °C to 30 °C; ≤ 75 % at 30 °C to 40 °C
Working humidity, 40 MΩ range
≤ 80 % at 10 °C to 30 °C; ≤ 70 % at 30 °C to 40 °C
Altitude
Working elevation
2000 m
Storage altitude
12,000 m
Temperature coefficient
0.1 X (specified accuracy) / °C (<18 °C or >28 °C)
Current input fuse protection
11A, 1000V fast-melting type, must use Fluke designated parts
The Fluke 107 is a compact, palm size easy-to-use digital multimeter made to fit the way you work. It is the perfect first-pass troubleshooting tool; small enough to fit in a shirt pocket yet tough enough to withstand daily use, including a 1-meter drop test. For everyday applications where true-rms accuracy isn’t needed, the Fluke 107 delivers reliable measurements time after time. With a CAT III 600 V safety rating, you don’t need to compromise safety. The Fluke 107 offers a comfortable grip, weight only 200 g, and is easy to carry.
Key features
CAT III 600 V safety rating
Current and voltage measurements
Measures resistance and continuity to check for broken wires
Data hold and backlit display to keep you working safe and fast
AC and DC voltage
AC and DC current
Resistance
Capacitance
Diode
Frequency and duty-cycle
Fluke 107 comes ready to work
The Fluke 107 comes with a TL75 Hard Point™ Test Lead Set. It’s one pair (red, black) of 48 inch (1.22 meter) test leads with right-angle, shrouded banana plugs. The meter also includes a SmartStrap™ intelligent magnetic multi-purpose lanyard that lets you hang the Fluke 107 from any ferrous surface or support the meter at an angle for easy viewing.
Specifications
Precision specifications
AC voltage(40 Hz to 500 Hz)1
Range
Resolution
Accuracy
6.000 V
0.001 V
1.0 % + 3
60.00 V
0.01 V
600.0 V
0.1 V
DC voltage
6.000 V
0.001 V
0.5 % + 3
60.00 V
0.01 V
600.0 V
0.1 V
Exchange millivolts
600.0 mV
0.1 mV
3.0 % + 3
Diode test2
2.000 V
0.001 V
10 %
Resistance (ohm)
400.0 Ω
0.1 Ω
0.5 % + 3
4.000 kΩ
0.001 kΩ
0.5 % + 2
40.00 kΩ
0.01 kΩ
0.5 % + 2
400.0 kΩ
0.1 kΩ
0.5 % + 2
4.000 MΩ
0.01 MΩ
1.5% + 3
Capacitor3
50.00 nF
0.01 nF
2 % + 5
500.0 nF
0.1 nF
2 % + 5
5.000 μF
0.001 μF
5 % + 5
50.00 μF
0.01 μF
5 % + 5
500.0 μF
0.1 μF
5 % + 5
1000 μF
1 μF
5 % + 5
Frequency4 Hz (10 Hz – 100 kHz)
50.00 Hz
0.01 Hz
0.1 % + 3
500.0 Hz
0.1 Hz
5.000 kHz
0.001 kHz
50.00 kHz
0.01 kHz
100.0 kHz
0.1 kHz
Duty cycle4
1 % to 99 %
0.10 %
1 % typical case5
AC current (40 Hz - 200 Hz)
4.000 A
0.001 A
1.5 % + 3
10.00 A
0.01 A
DC
4.000 A
0.001 A
1.5 % + 3
10.00 A
0.01 A
All AC current, frequency, and duty cycle are specified from 1% to 100% of the range. Input values below 1% of range are not specified.
Typically, the open circuit test voltage is 2.0 V and the short circuit current is < 0.6 mA.
The parameters do not include errors due to test lead capacitance and capacitor substrate (up to 1.5 nF in the 50 nF range).
All AC current, frequency, and duty cycle are specified from 1% to 100% of the range. Input values below 1% of range are not specified.
Typically, the frequency is 50 Hz or 60 Hz and the duty cycle is 10% to 90%.
Features
Overload protection
Input impedance (nominal value)
Common mode rejection ratio
Normal mode rejection ratio
AC voltage
600 V 1
>10 MΩ <100 pF 2
>60 dB at 50 Hz or 60 Hz at DC current
-
Exchange millivolts
600 mV
>1M, <100 pF
>80 dB at 50 Hz or 60 Hz
-
DC voltage
600 V 1
>10 MΩ <100 pF
>100 dB at 50 Hz or 60 Hz at DC current
>60 dB at 50 Hz or 60 Hz
Up to 6 x 105 V Hz
For medium voltage (alternating current), the input impedance is approximately 1 MΩ.
General technical indicators
The highest voltage applied to any terminal and ground
600 V
Display (LCD)
6000 counts, updated three times per second
Type of battery
Two AAA batteries (NEDA 24A, IEC LR03)
Battery life
200 hours
Temperature
Operating temperature
0 °C to 40 °C
Storage temperature
-30 °C to 60 °C
Relative humidity
Working humidity
No condensation below 10 °C ≤ 90 % at 10 °C to 30 °C; ≤ 75 % at 30 °C to 40 °C
Working humidity, 40 MΩ range
≤ 80 % at 10 °C to 30 °C; ≤ 70 % at 30 °C to 40 °C
Altitude
Working elevation
2000 m
Storage altitude
12,000 m
Temperature coefficient
0.1 X (specified accuracy) / °C (<18 °C or >28 °C)
Current input fuse protection
11A, 1000V fast-melting type, must use Fluke designated parts