The Fluke 106 is a compact, easy-to-use multimeter made to fit the way you work. It is the perfect first-pass troubleshooting tool: small enough to fit in a shirt pocket or work bag, tough enough to withstand daily use, and extremely simple to use. All without compromising safety. For everyday applications, where true-rms accuracy isn’t needed, the Fluke 106 delivers reliable measurements time after time.
Key features
AC and DC voltage measurement
AC and DC current measurement
Resistance measurement
Capacitance measurement
Compact 142 mm x 69 mm x 28mm size
Specifications
Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, relative humidity at 0 % to 75 %. Accuracy specifications take the form of: ±([% of Reading] + [Number of Least Significant Digits])
Accuracy Specifications
Function
Range
Resolution
Accuracy
AC Volts
6.000 V
0.001 V
1.0 % + 3
60.00 V
0.01 V
600.0 V
0.1 V
DC Volts
6.000 V
0.001 V
0.5 % + 3
60.00 V
0.01 V
600.0 V
0.1 V
AC Millivolts
600.0 mV
0.1 mV
3.0 % + 3
Resistance (Ohms)
400.0 Ω
0.1 Ω
0.5 % + 3
4.000 kΩ
0.001 kΩ
0.5 % + 2
40.00 kΩ
0.01 kΩ
0.5 % + 2
400.0 kΩ
0.1 kΩ
0.5 % + 2
4.000 MΩ
0.001 MΩ
0.5 % + 2
40.00 MΩ
0.01 MΩ
1.5% + 3
Capacitance2
50.00 nF
0.01 nF
2 % + 5
500.0 nF
0.1 nF
2 % + 5
5.000 μF
0.001 μF
5 % + 5
50.00 μF
0.01 μF
5 % + 5
500.0 μF
0.1 μF
5 % + 5
1000 μF
1 μF
5 % + 5
AC Current (40 Hz to 200 Hz)
4.000 A
0.001 A
1.5 % + 3
10.00 A
0.01 A
DC Current
4.000 A
0.001 A
1.5 % + 3
10.00 A
0.01 A
All AC are specified from 1 % to 100 % of range. Inputs below 1 % of range are not specified.
Specifications do not include errors due to test lead capacitance and capacitance floor (may be up to 1.5 nF in the 50 nF range).
Function
Overload Protection
Input Impedance (Nominal)
Common Mode Rejection Ratio
Normal Mode Rejection Ratio
AC Volts
600 V 1
>10 MΩ <100 pF 2
>60 dB at dc, 50 Hz or 60 Hz
−
\AC Millivolts
600 mV
>1M <100 pF
>80 dB at 50 Hz or 60 Hz
−
DC Volts
600 V 1
>10 MΩ <100 pF
>100 dB at dc, 50 Hz or 60 Hz
>45 dB at 50 Hz or 60 Hz
6 x 105 V Hz Max
For mV (AC), input impedance is approximately 1 MΩ.
General Specifications
Maximum Voltage Between any Terminal and Earth Ground
600 V
Display (LCD)
6000 counts, updates 3/sec
Battery Type
2 AAA, NEDA 24A, IEC LR03
Battery Life
200 hours minimum
Temperature
Operating
0 °C to 40 °C
Storage
-30 °C to 60 °C
Relative Humidity
Operating Humidity
Non-condensing when <10°C ≤90 % at 10 °C to 30 °C; ≤75 % at 30 °C to 40 °C
Operating Humidity, 40 MΩ Range
≤80 % at 10 °C to 30 °C; ≤70 % at 30 °C to 40 °C
Altitude
Operating
2000 m
Storage
12,000 m
Temperature Coefficient
0.1 X (specified accuracy) /°C (<18 °C or >28 °C)
Fuse Protection for Current Inputs
11A, 1000V Fast Fuse, Fluke specified part only
Size (HxWxL)
142 mm x 69 mm x 28mm
Weight
200 g
IP Rating
IEC 60529: IP 40
Safety
IEC 61010-1: 600 V CAT III, Pollution Degree 2
Electromagnetic Environment
IEC 61326-1: Portable
Electromagnetic Compatibility
Applies to use the Korea only. Class A Equipment (Industrial Broadcasting and Communication Equipment)1
The Fluke 106 is a compact, easy-to-use multimeter made to fit the way you work. It is the perfect first-pass troubleshooting tool: small enough to fit in a shirt pocket or work bag, tough enough to withstand daily use, and extremely simple to use. All without compromising safety. For everyday applications, where true-rms accuracy isn’t needed, the Fluke 106 delivers reliable measurements time after time.
Key features
AC and DC voltage measurement
AC and DC current measurement
Resistance measurement
Capacitance measurement
Compact 142 mm x 69 mm x 28mm size
Specifications
Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, relative humidity at 0 % to 75 %. Accuracy specifications take the form of: ±([% of Reading] + [Number of Least Significant Digits])
Accuracy Specifications
Function
Range
Resolution
Accuracy
AC Volts
6.000 V
0.001 V
1.0 % + 3
60.00 V
0.01 V
600.0 V
0.1 V
DC Volts
6.000 V
0.001 V
0.5 % + 3
60.00 V
0.01 V
600.0 V
0.1 V
AC Millivolts
600.0 mV
0.1 mV
3.0 % + 3
Resistance (Ohms)
400.0 Ω
0.1 Ω
0.5 % + 3
4.000 kΩ
0.001 kΩ
0.5 % + 2
40.00 kΩ
0.01 kΩ
0.5 % + 2
400.0 kΩ
0.1 kΩ
0.5 % + 2
4.000 MΩ
0.001 MΩ
0.5 % + 2
40.00 MΩ
0.01 MΩ
1.5% + 3
Capacitance2
50.00 nF
0.01 nF
2 % + 5
500.0 nF
0.1 nF
2 % + 5
5.000 μF
0.001 μF
5 % + 5
50.00 μF
0.01 μF
5 % + 5
500.0 μF
0.1 μF
5 % + 5
1000 μF
1 μF
5 % + 5
AC Current (40 Hz to 200 Hz)
4.000 A
0.001 A
1.5 % + 3
10.00 A
0.01 A
DC Current
4.000 A
0.001 A
1.5 % + 3
10.00 A
0.01 A
All AC are specified from 1 % to 100 % of range. Inputs below 1 % of range are not specified.
Specifications do not include errors due to test lead capacitance and capacitance floor (may be up to 1.5 nF in the 50 nF range).
Function
Overload Protection
Input Impedance (Nominal)
Common Mode Rejection Ratio
Normal Mode Rejection Ratio
AC Volts
600 V 1
>10 MΩ <100 pF 2
>60 dB at dc, 50 Hz or 60 Hz
−
\AC Millivolts
600 mV
>1M <100 pF
>80 dB at 50 Hz or 60 Hz
−
DC Volts
600 V 1
>10 MΩ <100 pF
>100 dB at dc, 50 Hz or 60 Hz
>45 dB at 50 Hz or 60 Hz
6 x 105 V Hz Max
For mV (AC), input impedance is approximately 1 MΩ.
General Specifications
Maximum Voltage Between any Terminal and Earth Ground
600 V
Display (LCD)
6000 counts, updates 3/sec
Battery Type
2 AAA, NEDA 24A, IEC LR03
Battery Life
200 hours minimum
Temperature
Operating
0 °C to 40 °C
Storage
-30 °C to 60 °C
Relative Humidity
Operating Humidity
Non-condensing when <10°C ≤90 % at 10 °C to 30 °C; ≤75 % at 30 °C to 40 °C
Operating Humidity, 40 MΩ Range
≤80 % at 10 °C to 30 °C; ≤70 % at 30 °C to 40 °C
Altitude
Operating
2000 m
Storage
12,000 m
Temperature Coefficient
0.1 X (specified accuracy) /°C (<18 °C or >28 °C)
Fuse Protection for Current Inputs
11A, 1000V Fast Fuse, Fluke specified part only
Size (HxWxL)
142 mm x 69 mm x 28mm
Weight
200 g
IP Rating
IEC 60529: IP 40
Safety
IEC 61010-1: 600 V CAT III, Pollution Degree 2
Electromagnetic Environment
IEC 61326-1: Portable
Electromagnetic Compatibility
Applies to use the Korea only. Class A Equipment (Industrial Broadcasting and Communication Equipment)1